However, the flashing frequency will not double while the hazard warning lights mode is active. LED/lamp failure can be detected via current threshold monitoring (customconfigurable on request) for each of the 4 output channels resulting in a doubling of the flasher frequency (C2 function). When the supply voltage is connected to the hazard warning lights input or to the left and right turn signal inputs simultaneously the hazard warning lights function is activated. When the supply voltage is applied to the left or right turn signal input the unit starts flashing left or right immediately. ![]() ![]() If lights fail during flasher mode the flashing frequency on terminal C doubles (C2 function). Terminal C is the turn signal LED/lamp control output. ![]() The 2-terminal LED flasher comes with a polarity reverser that may be needed in some applications. ![]() This flasher unit supports left/right turn signals as well as hazard warning lights doubling flasher frequency in case of LED/lamp failure. LED turn signals use much less power than standard incandescent bulbs and wont work correctly with a standard flasher. The Universal Flasher LED is suitable for LED lights and lights with incandescent lamps. I installed a new LED headlight (Sunpie Daymaker) and new License Plate light (Sylvania) and I have my right turn signals (front and back) fast flashing.